| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113 |
- Unicode true
- Name "ZCode installer.nsh smoke"
- OutFile "${OUTPUT_FILE}"
- InstallDir "$TEMP\zcode-installer-nsh-smoke"
- RequestExecutionLevel user
- SilentInstall silent
- !addincludedir "${NSIS_INCLUDE_DIR}"
- !addincludedir "${ELECTRON_BUILDER_NSIS_INCLUDE_DIR}"
- !include "LogicLib.nsh"
- !ifndef BUILD_UNINSTALLER
- !include "MUI2.nsh"
- !include "StrContains.nsh"
- !endif
- !define APP_DESCRIPTION "ZCode NSIS smoke fixture"
- !define APP_FILENAME "ZCode"
- !define APP_ID "dev.zcode.installer-nsh-smoke"
- !define UNINSTALL_REGISTRY_KEY "Software\\ZCodeInstallerSmoke\\{7C2A992D-72BB-4F8C-8DF0-0EA8A7B1F1C3}"
- ; This fixture invokes the cleanup macro from a normal section; electron-builder's real uninstaller uses un.*.
- !ifdef BUILD_UNINSTALLER
- !define ZCODE_UNINSTALLER_FUNCTION_PREFIX ""
- !endif
- ; Simulate a manually launched overwrite installer without --updated.
- !define isUpdated `1 == 0`
- !define allowToChangeInstallationDirectory
- !define ZCODE_INSTALLER_DEFAULT_LOG_PATH "${DEFAULT_LOG_PATH}"
- !define ZCODE_INSTALLER_ELEVATED_LOG_PATH "${ELEVATED_LOG_PATH}"
- !ifdef FORCE_ELEVATED_INNER
- !define ZCODE_INSTALLER_IS_ELEVATED_INNER `1 == 1`
- !endif
- Var appExe
- Var launchLink
- Var newStartMenuLink
- Var newDesktopLink
- Var keepShortcuts
- !include "${ZCODE_INSTALLER_NSH}"
- ; 与正式构建保持顺序:common.nsh 的常量在自定义 include 之后才可用。
- !define UNINSTALL_FILENAME "uninstaller.exe"
- ; 回归原因:electron-builder 异步生成 header 时,自定义 include 可能先于插件目录注册。
- ; 普通场景使用真实 UAC 判据,避免恒假替身掩盖插件尚未可用的编译错误。
- !addplugindir /x86-unicode "${NSIS_PLUGIN_DIR}"
- !ifndef BUILD_UNINSTALLER
- !insertmacro customHeader
- !ifdef allowToChangeInstallationDirectory
- !error "customHeader must enable shortcut preservation for manual overwrite"
- !endif
- !insertmacro customPageAfterChangeDir
- Function .onInit
- !insertmacro preInit
- FunctionEnd
- !endif
- Section
- SetOutPath "$INSTDIR"
- File /oname=ZCode.exe "${FIXTURE_EXE}"
- StrCpy $appExe "$INSTDIR\ZCode.exe"
- StrCpy $launchLink "$INSTDIR\stale-target.exe"
- StrCpy $newStartMenuLink "$INSTDIR\start-menu.lnk"
- StrCpy $newDesktopLink "$INSTDIR\desktop.lnk"
- StrCpy $keepShortcuts "true"
- !ifdef PRECREATE_SHORTCUTS
- !ifdef STALE_SHORTCUTS
- CreateShortCut "$newStartMenuLink" "$INSTDIR\stale-target.exe" "--stale"
- CreateShortCut "$newDesktopLink" "$INSTDIR\stale-target.exe" "--stale"
- !else
- CreateShortCut "$newStartMenuLink" "$appExe" "--preserved"
- CreateShortCut "$newDesktopLink" "$appExe" "--preserved"
- !endif
- !ifndef BUILD_UNINSTALLER
- Push "$newStartMenuLink"
- Call ZCodeReadShortcutTarget
- Pop $R8
- FileOpen $0 "$INSTDIR\read-shortcut-target.txt" w
- FileWrite $0 "$R8"
- FileClose $0
- !endif
- !endif
- !ifndef BUILD_UNINSTALLER
- SetDetailsPrint none
- !insertmacro customInit
- ; The real electron-builder template invokes these hooks at the same points.
- !insertmacro customInstallSectionStarted
- !insertmacro customInstallCleanupStarted
- !insertmacro customInstallCleanupCompleted
- !insertmacro customInstallExtractStarted
- !insertmacro customInstallExtractCompleted
- !insertmacro customInstallShortcutsStarted
- !insertmacro customInstallShortcutsCompleted
- !insertmacro customInstall
- !endif
- FileOpen $0 "$INSTDIR\launch-link.txt" w
- FileWrite $0 "$launchLink"
- FileClose $0
- ; Expand cleanup diagnostics in the uninstaller smoke fixture so /WX checks the reference.
- !ifdef BUILD_UNINSTALLER
- !insertmacro customRemoveFiles
- !endif
- ; customInstall 会向夹具专属注册表键写入 InstallLocation,运行后必须清理,
- ; 不能在测试机上留下残留(spec:夹具不得写入真实注册表)。
- DeleteRegKey HKCU "Software\ZCodeInstallerSmoke"
- SectionEnd
|